Dtsch Med Wochenschr ; 148(8): 475-482, 2023 Apr.
Artigo em Inglês, Alemão | MEDLINE | ID: covidwho-2266864

RESUMO

In case of hypoxemia, the oxygen content is often still in the lower normal range, so that there is no hypoxia in the tissue. If the hypoxia-threshold is reached in the tissue in hypoxic, anemic and also cardiac-related hypoxemia, identical counterregulations occur in the cell metabolism, regardless of the cause of hypoxemia. In clinical practice, this pathophysiologic fact is sometimes ignored, although depending on the cause of hypoxemia, assessment and therapy vary widely. While restrictive and generally accepted rules are specified in the transfusion guidelines for anemic hypoxemia, in the case of hypoxic hypoxia, the indication for invasive ventilation is made very early. The clinical assessment and indication are limited to the parameters oxygen saturation, oxygen partial pressure and oxygenation index. During the corona pandemic, misinterpretations of pathophysiology have become evident and may have led to unnecessary intubations. However, there is no evidence for the treatment of hypoxic hypoxia with ventilation. This review addresses the pathophysiology of the different types of hypoxia focusing on the problems associated with intubation and ventilation in the intensive care unit.


Assuntos
Anemia , Hipóxia , Humanos , Hipóxia/etiologia , Hipóxia/terapia , Anemia/terapia , Anemia/complicações , Pulmão , Unidades de Terapia Intensiva , Oxigênio/uso terapêutico
2.
Gesundheitswesen ; 84(7): 566-574, 2022 Jul.
Artigo em Alemão | MEDLINE | ID: covidwho-1931523

RESUMO

The relevance of aerosols for the transmission of the Severe Acute Respiratory Syndrome Coronavirus Type 2 (SARS-CoV-2) is still debated. However, over time, in addition to distancing and hygiene rules, aerosol physics-based measures such as wearing face masks and ventilating indoor spaces were found to be efficient in reducing infections. In an interdisciplinary workshop "Aerosol & SARS-CoV-2" of the Association for Aerosol Research (GAeF) in cooperation with the German Society for Pneumology and Respiratory Medicine (DGP), the Professional Association of General Air Technology of the VDMA, the German Society for Virology (GfV), the Health Technology Society (GG) and the International Society for Aerosols in Medicine (ISAM) under the auspices of the Robert Koch Institute (RKI) in March 2021, the need for research and coordination on this topic was addressed. Fundamental findings from the various disciplines as well as interdisciplinary perspectives on aerosol transmission of SARS-CoV-2 and infection mitigation measures are summarized here. Finally, open research questions and needs are presented.


Assuntos
COVID-19 , Aerossóis , COVID-19/prevenção & controle , Alemanha , Humanos , Máscaras , SARS-CoV-2
3.
ERJ Open Res ; 7(2)2021 Apr.
Artigo em Inglês | MEDLINE | ID: covidwho-1286809

RESUMO

Treat hypoxia, not hypoxaemia https://bit.ly/3hwPLCL.

4.
ERJ Open Res ; 7(2)2021 Apr.
Artigo em Inglês | MEDLINE | ID: covidwho-1181081

RESUMO

This correspondence argues that happy hypoxaemic patients should not be intubated as long as they remain happy https://bit.ly/3csrpWO.

5.
ERJ Open Res ; 7(1)2021 Jan.
Artigo em Inglês | MEDLINE | ID: covidwho-1143169

RESUMO

BACKGROUND: Invasive mechanical ventilation of hypoxaemic coronavirus disease 2019 (COVID-19) patients is associated with mortality rates of >50%. We evaluated clinical outcome data of two hospitals that agreed on a predefined protocol for restrictive use of invasive ventilation where the decision to intubate was based on the clinical presentation and oxygen content rather than on the degree of hypoxaemia. METHOD: Data analysis was carried out of patients with positive PCR-testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), typical history, and symptoms and pulmonary infiltrates who exhibited oxygen saturation values of <93%. RESULTS: We identified 78 patients who met the inclusion criteria. The oxygen saturation nadir was 84.4±6.5% for the whole group. 53 patients (68%) received nasal oxygen (group 1), 17 patients (22%) were treated with nasal high-flow continuous positive airway pressure (CPAP), noninvasive ventilation or a combination thereof (group 2), and eight patients (10%) were intubated (group 3). The Horovitz index was 216±8 for group 1, 157±13 for group 2 and 106±15 for group 3. Oxygen content was 14.5±2.5, 13.4±1.9 and 11.6±2.6 mL O2·dL-1 for the three respective groups. Overall mortality was 7.7%; the mortality of intubated patients was 50%. Overall, 93% of patients could be discharged on room air. CONCLUSION: Permissive hypoxaemia where decisions for the level of respiratory therapy were based on the clinical presentation and oxygen content resulted in low intubation rates, low overall mortality and a low number of patients who require oxygen after discharge.

6.
J Occup Environ Hyg ; 18(3): 118-127, 2021 03.
Artigo em Inglês | MEDLINE | ID: covidwho-1066172

RESUMO

During the beginning of the SARS-CoV-2 pandemic, there was a shortage of masks and respirators for the protection of health care professionals. Masks for noninvasive ventilation (NIV) in combination with viral-proof filters, worn by healthcare workers, could serve as an alternative protection measure. We determined the simulated protection factor (SPF) of such devices in comparison to conventional surgical masks, N95, and FFP3 respirators. Masks and respirators were mounted on a ventilated mannequin head in a test-chamber. Isotonic saline containing 150 MBq 99mTC-DTPA (99mTc-diethylenetriamine pentaacetate (DTPA) was nebulized inside the box. The aerosol had a mass median aerodynamic diameter of 0.6 ± 0.4 µm. SPFs were measured using radioactive DTPA particles in the mannequin test system by calculating the ratio of unfiltered particles (Pu) and filtered particles (Pf) for each tested device (SPF = Pu/Pf). Simulated protection factors were 15.6 ± 3.6 for a ResMed AcuCare mask plus filter, 3.5 ± 0.2 for a ResMed Mirage Quattro FX mask plus filter, 9.5 ± 0.8 for a Loewenstein JOYCEclinc FF mask plus filter, 1.9 ± 0.2 for a surgical mask with a rubber band, 2.7 ± 0.7 for a surgical mask with ribbons, 2.3 ± 0.3 for an FFP3 respirator, and 3.6 ± 1.3 for an N95 respirator. The ResMed AcuCare and the Loewenstein JOYCEclinic FF mask were more effective than any other of the tested devices (p < 0.001). In conclusion, masks normally used for NIV with viral-proof filters can effectively filter respirable particles.


Assuntos
COVID-19/prevenção & controle , Máscaras , Dispositivos de Proteção Respiratória , Filtração/instrumentação , Manequins , Respiradores N95 , Ventilação não Invasiva/instrumentação , Exposição Ocupacional/prevenção & controle , SARS-CoV-2 , Pentetato de Tecnécio Tc 99m
7.
PLoS One ; 15(8): e0237899, 2020.
Artigo em Inglês | MEDLINE | ID: covidwho-721928

RESUMO

OBJECTIVE: Pandemic scenarios like the current Corona outbreak show the vulnerability of both globalized markets and just-in-time production processes for urgent medical equipment. Even usually cheap personal protection equipment becomes excessively expensive or is not deliverable at all. To avoid dangerous situations especially to medical professionals, but also to affected patients, 3D-printer and maker-communities have teamed up to develop and print shields, masks and adapters to help the medical personnel. In this study, we investigate three home-made respiratory masks for filter and protection efficacy and discuss the results and legal aspects. MATERIALS AND METHODS: A home-printed respiratory mask with a commercial filter, a scuba-diving mask with a commercial filter and a mask sewn from a vacuum cleaner bag were investigated with 99mTc-labeled NaCl-aerosol, and the respective filter-efficacy was measured under a scintigraphic camera. RESULTS: The sewn mask from a vacuum cleaner bag had a filter efficacy of 69.76%, the 3D-printed mask of 39.27% and the scuba-diving mask of 85.07%. CONCLUSION: Home-printed personal protection equipment can be a-yet less efficient-alternative against aerosol in case professional masks are not available, but legal aspects of their use and distribution have to be kept in mind in order to avoid compensation claims.